Items To Be Inspected

Address Visibility

Arvada rental property address with fire department inspection marker

Your property address must be clearly posted and visible from the street. This allows emergency responders to locate the property quickly in any condition.

Smoke & CO Alarms

Smoke detector installed on ceiling during Arvada rental inspection

Smoke and carbon monoxide alarms are required inside every bedroom, outside each sleeping area, and on every level including the basement. All alarms must be interconnected — either hardwired or Bluetooth — so all units trigger simultaneously.

Fire Extinguishers

Fire extinguisher inspected for Arvada rental property safety compliance

A minimum Type 2A:10BC fire extinguisher is required on every floor of the property. Fire-resistance ratings of all rated walls, doors and assemblies must be maintained.

Stairways, Decks & Balconies

Interior stairway inspected for safe egress in Arvada rental property

All stairways, decks, porches and balconies must be structurally sound, in good repair, and properly anchored to support imposed loads. Handrails and guardrails are inspected for stability and code compliance.

Room Dimensions

Bedroom interior inspected during Arvada rental property inspection

Every habitable room must measure at least 7 feet in any direction, have a minimum of 70 square feet of floor area, and maintain a ceiling height of at least 7 feet. Rooms that do not meet these minimums cannot be used or advertised as sleeping spaces.

Heating

Heating system inspected during Arvada rental property inspection

Heating equipment must be properly installed, safely maintained, and capable of maintaining a minimum indoor temperature of 68°F year-round in all habitable spaces. All fuel-burning appliances are inspected for safe operation.

Electrical Systems

Electrical outlet inspected during Arvada rental property inspection

All electrical equipment, wiring and appliances must be properly installed and maintained in a safe, code-compliant manner. Inspectors check outlets, fixtures, panels and wiring for hazards, improper installations and unpermitted work.

Natural Lighting

Windows inspected for emergency egress and safety during Arvada rental inspection

Every habitable room must receive natural light equal to at least 8% of the room's floor area through windows or skylights. Artificial lighting may substitute only where specifically allowed by code.

Ventilation

Ventilation system inspected during Arvada rental property inspection

Every habitable space must have at least one openable window to provide fresh air and ventilation. Exceptions apply only where mechanical ventilation systems meet code requirements.

Plumbing Fixtures

Plumbing fixtures inspected during Arvada rental property inspection

All plumbing fixtures must be properly installed, functional, sanitary and free of leaks or defects. Toilets, sinks, showers and tubs are inspected for safe and proper operation.

Water Supply & Pressure

Water supply and pressure tested during Arvada rental property inspection

The water supply system must deliver adequate volume and pressure to all plumbing fixtures throughout the property. Systems are inspected for leaks, defects and the ability to function safely under normal demand.

Water Heater

Water heater inspected during Arvada rental property inspection

Water heating equipment must supply hot water to every fixture at a minimum temperature of 110°F. An approved temperature and pressure relief valve with proper discharge pipe must be installed and maintained on all water heaters.

Pest & Vermin Free

Property inspected for pest and vermin issues during Arvada rental inspection

The structure and all interior spaces must be free of pests, rodents and vermin at the time of inspection. Evidence of active infestation is a failing condition requiring remediation before permit approval.

Bathroom Privacy

Bathroom privacy features inspected during Arvada rental property inspection

Every bathroom and toilet room must provide privacy, including a door with a functioning interior lock. Bathrooms cannot serve as the only passageway to another room or to the exterior of the unit.

Egress & Emergency Escape

Emergency egress and escape routes inspected during Arvada rental property inspection

A safe, continuous and unobstructed path of travel must exist from every point in the structure to a public way. Emergency escape and rescue openings must comply with the code under which the building was originally constructed.

Doors & Hardware

Doors and hardware inspected during Arvada rental property inspection

All doors and hardware must be in good condition with locks that securely latch and provide occupant security. Exterior doors are inspected for condition, operation and the ability to be secured from the inside.